Server Tech

Server Technology has provided power solutions for labs, data centers, and telecommunications operations for 30 years. Over 60,000 customers around the world rely on their power distribution units and award-winning power management solutions to reduce downtime, facilitate capacity planning, improve energy utilization, and drive efficiency.

HDOT Cx

Server Tech's award-winning High Density Outlet Technology (HDOT) rack PDU has been improved with our Cx outlet – a UL tested hybrid of the C13 and C19 outlets. Cx accommodates both C20 and C14 plugs, increasing density while providing ultimate flexibility. Learn more

POPS® (Per Outlet Power Sensing)

Provides power monitoring per individual outlet for Smart or Switched PDUs. Power information includes current, voltage, power (kW), apparent power, crest factor, and power factor. Using our grouping technology, power information is available per device, of devices (application), individual PDU, or cabinet. Learn more

PIPS (Per Inlet Power Sensing)

PIPS technology replaces monitoring at the remote power panel in data centers with higher accuracy and lower cost monitoring of each power circuit attached to a PDU. Learn more

Pro2 Platform (Firmware)

Improve uptime by maintaining high availability to your data through redundantly powered hot-swappable net-work cards and multi-link capability. Gain additional insight into rising loads or heat through multi-level alarms.

Smart Power Distribution Unit

Easy to use and access, CEG can provide Smart PDUs that offer true RMS input current monitors on easy-to-view LED via network or serial connection. These PDUs feature branch circuit protection and are available in a variety of voltages, amperages. Available in single- and three-phase.

Our Server Tech Smart PDUs are guaranteed secure and feature external authentication and authorization support, while SNMP traps provide automated alerts surrounding each outlet’s power and environmental conditions. Optional temperature and humidity probes, with 10 ft. cords, offer flexibility in terms of sensor placement.

Switched Power Distribution Unit

With the ability to turn on, off or reboot outlets individually or as a group, Switched PDUs from Server Tech also feature outlet lock-out, power-up sequencing to reduce power-up inrushes and optional smart load shedding. Switched PDUs feature Smart PDU abilities for network access to power and environmental information.

Metered Power Distribution Unit

When affordable and reliable power distribution for all devices in the equipment cabinet is required, Metered PDUs are the perfect solution. Auto-flip current displays help prevent overloads and simplify three-phase load balancing in high density cabinets, while flexible mounting solutions provide for a basic installation.

Basic Power Distribution Unit

When your greatest concern is delivering reliable, consistent power, CEG can provide a basic PDU that’s a dependable everyday solution for your data center. With branch circuit protection, these PDUs from Server Tech meet UL and IEC data center requirements. Optional flexible mounting and color identification features are available.

Fail-Safe Power Redundancy

Available in metered, smart and switched options, these PDUs offer branch circuit protection. Switched versions feature outlet control, temperature humidity monitoring, linkable expansion and network monitoring.

Our Server Tech FSTS PDUs allow you to receive SNMP-based notifications. Cycle power to individual outlets or groups of outlets in order to reboot servers or power off unused receptacles using outlet control.

ServerTech’s Powerful Feature Set

CDU Key Features_Icon_Branch Circuit Protection-01

Branch Circuit Protection PDUs are UL 60950-1 certified for branch circuit protection and use fuses or circuit breakers to protect each outlet branch.

CDU Key Features_Icon_Input Current Monitor-01

Input Current Monitoring LEDs display current per phase to help prevent over-loads & simplify 3-phase load balancing in high density cabinets

CDU Key Features_Icon_Enviromental Monitoring-01

Temperature/Humidity Monitoring Master and Link units each support two external 10’ (3m) T/H probes. Receive SNMP-based alerts and email notifications.

CDU Key Features_Icon_Linkable Expansion-01

Linked Expansion Exclusive method for linking additional PDUs together under a single IP address with support for A & B power in-feeds.

CDU Key Features_Icon_Multi-Link Expansion-01

Star Multi-link Expansion Kit (Pro2 only) provides the ability to link up to four power circuits using one IP address. Kit sold separately.

CDU Key Features_Icon_Access-Security-01

IP Access, Security & Communications Web, SSH, Telnet, SNMPv2c & v3, RS-232 serial, 10/100 Base T-Ethernet, LDAP(S), TACACS+, RADIUS, DHCP, & SMTP/email

CDU Key Features_Icon_IndividualOutletControl-01

Outlet Control on Switched PDUs, cycle power to individual outlets or groups of outlets to reboot servers; or power off unused receptacles.

CDU Key Features_Icon_POPS-01

POPS® (Per Outlet Power Sensing) Monitor Current Load (A), Voltage (V), Power (W), Apparent Power (VA), Crest Factor, Power Factor, and Energy per outlet.

CDU Key Features_Icon_PIPS-01

PIPS® (Per Inlet Power Sensing) Monitor Current Load (A), Voltage (V), Power (W), Apparent Power (VA), Crest Factor, Power Factor, & Energy per inlet.

Print

The HDOT® Cx outlet is a hybrid of the C13 and C19 outlets. Cx outlets accommodate C20 and C14 plugs, increasing density while providing ultimate flexibility.

CDU Key Features_Icon_HDOT-01

HDOT® (High Density Outlet Technology) Maximize outlet density with our uniquely designed, high density modules for standard C13 & C19 outlets

CDU Key Features_Icon_Alt_Phase-01-01

Alternating Phase Phased power is alternated between each outlet, instead of each branch, which simplifies load balancing and clutter.

CDU Key Features_Icon_BranchCurrentMonitoring-01

Branch Current Monitoring PRO2 monitors current at each breaker/fuse branch and alerts when high usage risks a tripped circuit.

CDU Key Features_Icon_High-Temp-01

High Temperature Rating Products are tested and approved for safe and reliable operation in 60˚C (140˚F) data center environments.

CDU Key Features_Icon_HotSwappable-01

Hot Swappable Network Card with Backup Power (Pro2 only) Network access is ensured when power is lost to the Master unit.

CDU Key Features_Icon_Power Pivot-01

Power Pivot™ The 90˚ rotatable power cord allows for standardized deployment at any facility no matter where power must be routed.

CDU Key Features_Icon_Flexible Mounting-01

Flexible Mounting Includes standard button mounts along with provisions for custom mounting brackets (contact Server Tech for details).

CDU Key Features_Icon_Retention Clip-01

Cable Retention Reduces accidental disconnects by ensuring that power cords are solidly connected to their respective devices.

CDU Key Features_Icon_Colors-01

Color Coded PDUs Select from six colors to designate PDU circuits in the data center — black, white, red, green, blue, and yellow.

StartUp Stick-01

Startup Stick™ The quick and easy solution to CDU configuration when DHCP is not available.

Sentry Power Manager

Sentry Power Manager is now available for a 120-Day Free Trial